- Home
- Density Test Report Report ID: 85194
- Edit Download Report
Density Test Report
Date :09/05/2025
Project No :2025C160
Client Company :Artisan
Arrival Time :09/05/2025 08:00
Onsite Hours :01:30
Name of the Project :Rockmart Township - 115 Felton Drive
Project Location :Rockmart
Weather :sunny
Departure Time :09/05/2025 09:30
ASEC Technician Name :Sean Willett
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 09/05/2025 | 1 | 14 | 103.2 | 2025-025 SP | 104.5 | 13.2 | 98.8 | 98 | D6938 | Pass |
| Location : | Lot #59, Elv/Depth :at finished grade | |||||||||
| Comment : | Gauge Serial No. :77-19952 | |||||||||
| 09/05/2025 | 2 | 18.8 | 104.0 | 2025-012 SP | 105.6 | 18.9 | 98.5 | 98 | D6938 | Pass |
| Location : | Lot #58, Elv/Depth :at finished grade | |||||||||
| Comment : | Gauge Serial No. :77-19952 | |||||||||
| 09/05/2025 | 3 | 19.8 | 103.5 | 2025-012 SP | 105.6 | 18.9 | 98.0 | 98 | D6938 | Fail |
| Location : | Lot #57, Elv/Depth :at finished grade | |||||||||
| Comment : | Gauge Serial No. :77-19952 | |||||||||
| 09/05/2025 | 4 | 23.2 | 88.4 | 2025-012 SP | 105.6 | 18.9 | 83.7 | 98 | D6938 | Fail |
| Location : | Lot #170, Elv/Depth :at finished grade | |||||||||
| Comment : | In-situ moisture content much higher than optimum. | Gauge Serial No. :77-19952 | ||||||||
| 09/05/2025 | 5 | 17.3 | 91.8 | 2025-012 SP | 105.6 | 18.9 | 86.9 | 98 | D6938 | Fail |
| Location : | Lot #170, Elv/Depth :at finished grade | |||||||||
| Comment : | Recompaction required. | Gauge Serial No. :77-19952 | ||||||||
Technician Signature / DateSean Willett, September 5, 2025
Reviewer Name / DateKenneth Mosman, October 15, 2025