- Home
- Density Test Report Report ID: 85303
- Edit Download Report
Density Test Report
Date :09/08/2025
Project No :2025G234
Client Company :Artisan
Arrival Time :09/08/2025 08:00
Onsite Hours :07:30
Name of the Project :NW-7 Hills, Unit 3, PH 13 (Site #2)
Project Location :Dallas
Weather :Sunny
Departure Time :09/08/2025 15:30
ASEC Technician Name :Austin Coleman
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 09/08/2025 | 1 | 14.1 | 97.5 | FP-1 | 0 | Check | ||||
| Location : | Between Manhole A3 and A4, Elv/Depth :-6.0 feet | |||||||||
| Comment : | OM: 15.0% MDD: 102.0 | |||||||||
| 09/08/2025 | 2 | 15.1 | 94.1 | FP-1 | 0 | Infinity | D6938 | Pass | ||
| Location : | Between Manhole A3 and A4, Elv/Depth :-6.0 | |||||||||
| Comment : | Compaction failed on the proctor the check plug found | Gauge Serial No. :29588 | ||||||||
| 09/08/2025 | 3 | 15.2 | 97.9 | FP-1 | 0 | Infinity | D6938 | Pass | ||
| Location : | Between Manhole A3 and A4, Elv/Depth :-6.0 | |||||||||
| Comment : | Re check passed, 96% compaction | Gauge Serial No. :29588 | ||||||||
| 09/08/2025 | 4 | 15.9 | 99.7 | FP-1 | 0 | Infinity | D6938 | Pass | ||
| Location : | Between Manhole A4 and A5, Elv/Depth :-5.0 | |||||||||
| Comment : | Compaction is passing at 97.7% | Gauge Serial No. :29588 | ||||||||
| Check | ||||||||||
| Location : | , Elv/Depth : | |||||||||
| Comment : | ||||||||||
Technician Signature / DateAustin Coleman, September 8, 2025