- Home
- Density Test Report Report ID: 85686
- Edit Download Report
Density Test Report
Date :09/04/2025
Project No :2025C215
Client Company :Artisan
Arrival Time :09/04/2025 9:30
Onsite Hours :08:30
Name of the Project :NW Unit 4 Parkway Ext. Phase 1
Project Location :Dallas
Weather :sunny
Departure Time :09/04/2025 18:00
ASEC Technician Name :Aminullah Azimi
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 09/04/2025 | 1 | 16.5 | 112.4 | 2025-031 SP | 101.0 | 20.7 | 95.5 | 95 | D6938 | Pass |
| Location : | Lot #9, Elv/Depth :1 foot below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 09/04/2025 | 2 | 16.7 | 96.3 | 2025-031 SP | 101.0 | 20.7 | 95.3 | 95 | D6938 | Pass |
| Location : | Lot #8, Elv/Depth :1 foot below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 09/04/2025 | 3 | 17.1 | 112.7 | 2025-031 SP | 101.0 | 20.7 | 95.2 | 95 | D6938 | Pass |
| Location : | Lot #10, Elv/Depth :1 foot below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 09/04/2025 | 4 | 15.8 | 96.7 | 2025-031 SP | 101.0 | 20.7 | 95.7 | 95 | D6938 | Pass |
| Location : | Lot #11, Elv/Depth :3 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 09/04/2025 | 5 | 12.6 | 99.5 | 2025-033 SP | 104.0 | 16.2 | 95.7 | 95 | D6938 | Pass |
| Location : | Lot #7, Elv/Depth :3 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
Technician Signature / DateAminullah Azimi, September 4, 2025
Reviewer Name / DateKenneth Mosman, October 16, 2025