- Concrete Test Report Report ID: 85919
- Edit Download Report
Concrete Test Report
Date :09/09/2025
Project No :2025C222
Client Company :C. W. MATTHEWS CONTRACTING CO., INC.
Arrival Time :
Onsite Hours :
Name of the Project :Rivian Plant, I-20 Ramp
Project Location :Rutledge
Weather :
Departure Time :
ASEC Technician Name :Russell Hendrix
Concrete Placement Information
Location(S):
N/A
Testing:
1 Set of concrete specimens (5 per set) were cast during the cast-in-place concrete pour at the above referenced location, in accordance with ASTM C31. The specimen will remain on site for the initial 24-48 hrs curing.
Compliance:
Field placement of concrete appeared to be in accordance with the project specifications (i.e., slump, temperature, etc) (refer to remarks below)
Deviations and/or noncompliances were noted during the field placement (refer to remarks below)
Specimen
Pick Up: 1 Sets of concrete specimens/ 5 specimen per set were picked up & transported to AS Engineering and Consulting LLC (ASEC) for curing and testing in accordance with ASTM C39, C670/1231
Pick Up: 1 Sets of concrete specimens/ 5 specimen per set were picked up & transported to AS Engineering and Consulting LLC (ASEC) for curing and testing in accordance with ASTM C39, C670/1231
Field Curing:
Specimen were stored for the initial 24 hours.
Near the poured structure
In an insulated curing box
Other
Remarks:
Concrete Core Sample.
Field Test Data
Specimen Type Selection : Cylinder
Set Number :N/A
Date Sampled :09/09/2025
Sampled By :Russell Hendrix
Contractor :N/A
Truck Number :N/A
Time Batched :N/A
Location of Placement :Old Mill 3043 Panel ST505+62
Number of samples cast :5
Ambient Temperature (°f) :N/A
Slump (in.) :N/A
Water added (gal.) :N/A
Laboratory Number :2025-041
Time Sampled :N/A
Weather Condition :N/A
Concrete Supplier :N/A
Mix ID :N/A
Quantity of Load (cu. yd.) :N/A
Sample Cast :1
Specified Strength :N/A
Concrete Temperature(°f) :N/A
Air Content (%) :N/A
Unit Weight (pcf) :N/A
Strength Test Results
| Specimen Number | Scheduled Test Date | Date Tested | Age (days) | Dia(in.) | Area (sq in.) | Maximum Loads (lbf) | Strength (lbs) | % Design Strength | Type of Fracture |
|---|---|---|---|---|---|---|---|---|---|
| 2 | 09/15/2025 | 09/15/2025 | 6 | 3.72 | 10.88 | 52965 | 4870 | Infinity | Type 2 |
| 3 | 09/15/2025 | 09/15/2025 | 6 | 3.72 | 10.87 | 55680 | 5120 | Infinity | Type 2 |
| 1 | 09/15/2025 | 09/15/2025 | 6 | 3.69 | 10.69 | 52229 | 4890 | Infinity | Type 2 |
| 4 | 09/15/2025 | 09/15/2025 | 6 | 3.71 | 10.82 | 55531 | 5130 | Infinity | Type 1 |
| 5 | 09/15/2025 | 09/15/2025 | 6 | 3.72 | 10.86 | 65372 | 6020 | Infinity | Type 2 |
UNLESS OTHERWISE SPECIFIED, TESTS WERE PERFORMED IN ACCORDANCE WITH ASTM TEST METHODS C31, C39, C138, C143, C173, AND C1064. FRACTURE TYPE INDICATED BY NUMBER.
(Type 1) Cone (Type 2) Cone-split (Type 3) Vertical (Type 4) Shear (Type 5) Edge Fracture (Type 6) Pointed
Technician Signature / DateRamchandra Mogulla, September 9, 2025
Reviewer Name / DateKenneth Mosman, October 27, 2025