Density Test Report
Date :09/29/2025
Project No :2025C216
Client Company :Artisan
Arrival Time :09/29/2025
Onsite Hours :
Name of the Project :NW (Lots) Unit 4 PH 1A & 1B
Project Location :Dallas
Weather :Sunny
Departure Time :09/29/2025
ASEC Technician Name :Sean Willett
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 09/29/2025 | 1 | 13.5 | 102.1 | 2025-036 SP | 107.0 | 18.5 | 95.4 | 95 | D6938 | Pass |
| Location : | SSMH B2, Elv/Depth :at finished grade | |||||||||
| Comment : | Gauge Serial No. :77-19952 | |||||||||
| 09/29/2025 | 2 | 13.3 | 102.1 | 2025-036 SP | 107.0 | 18.5 | 95.4 | 95 | D6938 | Pass |
| Location : | SSMH B2, Elv/Depth :at finished grade | |||||||||
| Comment : | Gauge Serial No. :77-19952 | |||||||||
| 09/29/2025 | 3 | 17 | 103.8 | 2025-036 SP | 107.0 | 18.5 | 97.0 | 95 | D6938 | Pass |
| Location : | SSMH B3, Elv/Depth :at finished grade | |||||||||
| Comment : | Gauge Serial No. :77-19952 | |||||||||
Technician Signature / DateSean Willett, September 29, 2025
Reviewer Name / DateKenneth Mosman, October 17, 2025