- Home
- Density Test Report Report ID: 86676
- Edit Download Report
Density Test Report
Date :09/16/2025
Project No :2025C215
Client Company :Artisan
Arrival Time :09/16/2025 08:00
Onsite Hours :07:30
Name of the Project :NW Unit 4 Parkway Ext. Phase 1
Project Location :Dallas
Weather :Sunny
Departure Time :09/16/2025 15:30
ASEC Technician Name :Austin Coleman
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 09/16/2025 | 1 | 12.8 | 106.0 | FP | 0 | Check | ||||
| Location : | MH A9-A11, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | 107.7 pcf maximum dry density @ 13.0% optimum moisture content. | |||||||||
| 09/16/2025 | 2 | 12.2 | 105.1 | 2025-035 SP | 107.8 | 13.0 | 97.5 | 95 | D6938 | Pass |
| Location : | A9-A10, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :29588 | |||||||||
| 09/16/2025 | 3 | 11.2 | 105.8 | 2025-035 SP | 107.8 | 13.0 | 98.1 | 95 | D6938 | Pass |
| Location : | A10-A11, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :29588 | |||||||||
| 09/16/2025 | 4 | 11.3 | 107.5 | 2025-035 SP | 107.8 | 13.0 | 99.7 | 95 | D6938 | Pass |
| Location : | A9-A10, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :29588 | |||||||||
| 10/16/2025 | 5 | 12.1 | 107.3 | 2025-035 SP | 107.8 | 13.0 | 99.5 | 95 | D6938 | Pass |
| Location : | A10-A11, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :29588 | |||||||||
Technician Signature / DateAustin Coleman, September 16, 2025
Reviewer Name / DateKenneth Mosman, October 16, 2025