Density Test Report

Date :10/08/2025
Project No :2025C215
Client Company :Artisan
Arrival Time :10/08/2025 08:30
Onsite Hours :08:45
Name of the Project :NW Unit 4 Parkway Ext. Phase 1
Project Location :Dallas
Weather :Sunny
Departure Time :10/08/2025 17:15
ASEC Technician Name :Austin Coleman

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
10/09/2025 13.8 100.6 0 Check
Location : Lot #20, Elv/Depth :at finished grade
Comment : Field proctor performed previously with maximum dry density of 102.0 pcf @ 13.0% optimum moisture content
10/08/2025 1 13.9 116.3 2025-033 SP 104.0 16.2 98.2 98 D6938 Pass
Location : Lot 26, Elv/Depth :at finished grade
Comment : Gauge Serial No. :30942
10/08/2025 2 13.7 104.1 2025-033 SP 104.0 16.2 100.1 98 D6938 Pass
Location : Lot #26, Elv/Depth :at finished grade
Comment : Gauge Serial No. :30942
10/08/2025 3 13.8 99.7 2025-031 SP 101.0 20.7 98.7 98 D6938 Pass
Location : Lot #25, Elv/Depth :at finished grade
Comment : Gauge Serial No. :30942
10/08/2025 4 13.0 102.2 2025-033 SP 104.0 16.2 98.3 98 D6938 Pass
Location : Lot #25, Elv/Depth :at finished grade
Comment : Gauge Serial No. :30942
10/08/2025 5 13.8 99.3 2025-031 SP 101.0 20.7 98.3 98 D6938 Pass
Location : Lot #24, Elv/Depth :at finished grade
Comment : Gauge Serial No. :30942
10/08/2025 6 13.7 100.1 2025-031 SP 101.0 20.7 99.1 98 D6938 Pass
Location : Lot #24, Elv/Depth :at finished grade
Comment : Gauge Serial No. :30942
10/08/2025 7 14.2 100.2 2025-031 SP 101.0 20.7 99.2 98 D6938 Pass
Location : Lot #20, Elv/Depth :at finished grade
Comment : Gauge Serial No. :30942
10/08/2025 8 12.6 103.1 2025-033 SP 104.0 16.2 99.1 98 D6938 Pass
Location : Lot #20, Elv/Depth :at finished grade
Comment : Gauge Serial No. :30942
10/08/2025 9 13.3 100.5 2025-031 SP 101.0 20.7 99.5 98 D6938 Pass
Location : Lot #19, Elv/Depth :at finished grade
Comment : Gauge Serial No. :30942
10/08/2025 10 13.2 115.5 2025-033 SP 104.0 16.2 98.1 98 D6938 Pass
Location : Lot #19, Elv/Depth :at finished grade
Comment : Gauge Serial No. :30942
10/08/2025 11 13.8 116.3 2025-033 SP 104.0 16.2 98.3 98 D6938 Pass
Location : Lot #6, Elv/Depth :at finished grade
Comment : Gauge Serial No. :30942
10/08/2025 12 16.3 102.5 2025-033 SP 104.0 16.2 98.6 100 D6938 Fail
Location : Lot #6 Basement, Elv/Depth :at finished grade
Comment : Gauge Serial No. :30942
10/08/2025 13 13.9 116.5 2025-033 SP 104.0 16.2 98.4 99.3 D6938 Fail
Location : Lot #7, Elv/Depth :at finished grade
Comment : Gauge Serial No. :30942
10/08/2025 14 16.1 95.3 2025-031 SP 101.0 20.7 94.4 98 D6938 Fail
Location : Lot #7, Elv/Depth :at finished grade
Comment : Gauge Serial No. :30942
10/08/2025 15 13.2 100.4 2025-031 SP 101.0 20.7 99.4 98 D6938 Pass
Location : Lot #8, Elv/Depth :at finished grade
Comment : Gauge Serial No. :30942
10/08/2025 16 13.2 102.4 2025-033 SP 104.0 16.2 98.5 98 D6938 Pass
Location : Lot #9, Elv/Depth :at finished grade
Comment : Gauge Serial No. :30942
10/08/2025 17 13.0 104.2 2025-033 SP 104.0 16.2 100.2 98 D6938 Pass
Location : Lot #10, Elv/Depth :at finished grade
Comment : Gauge Serial No. :30942
10/08/2025 18 10.5 104.9 2025-033 SP 104.0 16.2 100.9 98 D6938 Pass
Location : Lot #10, Elv/Depth :at finished grade
Comment : Gauge Serial No. :30942
10/08/2025 19 12.2 102.5 2025-033 SP 104.0 16.2 98.6 98 D6938 Pass
Location : Lot #11, Elv/Depth :at finished grade
Comment : Gauge Serial No. :30942
10/08/2025 20 12.1 102.9 2025-033 SP 104.0 16.2 98.9 98 D6938 Pass
Location : Lot #11, Elv/Depth :at finished grade
Comment : Gauge Serial No. :30942
Technician Signature / DateAustin Coleman, October 8, 2025
Reviewer Name / DateKenneth Mosman, October 17, 2025