- Home
- Density Test Report Report ID: 86848
- Edit Download Report
Density Test Report
Date :10/13/2025
Project No :2025C224
Client Company :C. W. MATTHEWS CONTRACTING CO., INC.
Arrival Time :10/13/2025
Onsite Hours :
Name of the Project :PDK Airport - RUNWAY 3R-21L KEEL REPLACEMENT
Project Location :PDK AIRPORT, DEKALB County, GA
Weather :sunny
Departure Time :10/13/2025
ASEC Technician Name :Russell Hendrix
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 10/13/2025 | 1 | 7.8 | 119.4 | 2025-037-MP | 132.9 | 8.2 | 89.8 | 100 | D6938 | Fail |
| Location : | 1045, Elv/Depth : | |||||||||
| Comment : | Using Nova's proctor also failed compaction. Recommend recompaction and retesting. | Gauge Serial No. :38069 | ||||||||
| 10/13/2025 | 2 | 8.2 | 118.2 | 2025-037-MP | 132.9 | 8.2 | 88.9 | 100 | D6938 | Fail |
| Location : | 1040, Elv/Depth : | |||||||||
| Comment : | Using Nova's proctor also failed compaction. Recommend recompaction and retesting. | Gauge Serial No. :38069 | ||||||||
| 10/13/2025 | 3 ( retest) | 11 | 113.5 | 2025-037-MP | 132.9 | 8.2 | 85.4 | 100 | D6938 | Fail |
| Location : | 1030, Elv/Depth : | |||||||||
| Comment : | Using Nova's proctor also failed compaction. Recommend recompaction and retesting. | Gauge Serial No. :38069 | ||||||||
| 10/13/2025 | 4 restest | 7.9 | 117.7 | 2025-037-MP | 132.9 | 8.2 | 88.6 | 100 | D6938 | Fail |
| Location : | 1020, Elv/Depth : | |||||||||
| Comment : | Using Nova's proctor also failed compaction. Recommend recompaction and retesting. | Gauge Serial No. :38069 | ||||||||
| 10/13/2025 | 5 | 7.5 | 118.3 | 2025-037-MP | 132.9 | 8.2 | 89.0 | 100 | D6938 | Fail |
| Location : | 1015, Elv/Depth : | |||||||||
| Comment : | Using Nova's proctor also failed compaction. Recommend recompaction and retesting. | Gauge Serial No. :38069 | ||||||||
| 10/13/2025 | 6 | 9.2 | 117.6 | 2025-037-MP | 132.9 | 8.2 | 88.5 | 100 | D6938 | Fail |
| Location : | 1010, Elv/Depth : | |||||||||
| Comment : | Using Nova's proctor also failed compaction. Recommend recompaction and retesting. | Gauge Serial No. :38069 | ||||||||
| 10/13/2025 | 7 | 8.6 | 117.5 | 2025-037-MP | 132.9 | 8.2 | 88.4 | 100 | D6938 | Fail |
| Location : | 1005, Elv/Depth : | |||||||||
| Comment : | Using Nova's proctor also failed compaction. Recommend recompaction and retesting. | Gauge Serial No. :30869 | ||||||||
| 10/13/2025 | 8 | 10.2 | 118.4 | 2025-037-MP | 132.9 | 8.2 | 89.1 | 100 | D6938 | Fail |
| Location : | end of completed section, Elv/Depth : | |||||||||
| Comment : | Using Nova's proctor also failed compaction. Recommend recompaction and retesting. | Gauge Serial No. :38069 | ||||||||
Technician Signature / DateRussell Hendrix, October 13, 2025
Reviewer Name / DateKenneth Mosman, October 16, 2025