Skip to content

Density Test Report

Date :11/13/2025
Project No :2025C211
Client Company :Pulte
Arrival Time :11/13/2025 07:30
Onsite Hours :08:00
Name of the Project :Haley's Bluff - Philadelphia Rd.
Project Location :Jasper
Weather :Sunny
Departure Time :11/13/2025 15:30
ASEC Technician Name :Sean Willett

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
11/13/2025 1 20.7 95.8 FP 2 100.0 18.5 95.8 95 D6938 Pass
Location : Lot #3 and #4 area, Elv/Depth :1504
Comment : Field Proctor #3 : 100.5 pcf @ 20.5% optimum moisture Gauge Serial No. :77-19952
11/13/2025 2 17.3 97.4 FP 2 100.0 18.5 97.4 95 D6938 Pass
Location : Roadway in front of Lots #3 and #4, Elv/Depth :1504
Comment : Field Proctor #3 : 100.5 pcf @ 20.5% optimum moisture Gauge Serial No. :77-19952
11/13/2025 3 27.0 91.5 FP 2 100.0 18.5 91.5 95 D6938 Fail
Location : Lot #1 roadway, Elv/Depth :1506
Comment : Field Proctor #3 : 100.5 pcf @ 20.5% optimum moisture. Recompaction required. Contractor informed. Gauge Serial No. :77-19952
11/13/2025 4 (retest of Test #3) 21.8 97.5 FP 2 100.0 18.5 97.5 95 D6938 Pass
Location : Lot #1 roadway, Elv/Depth :1506
Comment : Field Proctor #3 : 100.5 pcf @ 20.5% optimum moisture Gauge Serial No. :77-19952
Technician Signature / DateSean Willett, November 13, 2025
Reviewer Name / DateKenneth Mosman, November 16, 2025