Skip to content

Density Test Report

Date :11/21/2025
Project No :2025C244
Client Company :McCallan Group
Arrival Time :11/21/2025 11:30
Onsite Hours :01:30
Name of the Project :Cassville Rd tract, proposed Burrito Wrap
Project Location :Cartersville
Weather :sunny
Departure Time :11/21/2025 13:00
ASEC Technician Name :Samara Simha Reddy Kandi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
11/21/2025 1 16.1 104.1 2025-051 106.4 19.3 97.8 95 D6938 Pass
Location : Building #14, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :38069
11/21/2025 2 12.8 100.1 2025-050 103.5 21.4 96.7 95 D6938 Pass
Location : Building #14, Elv/Depth :2 feet below finished grade
Comment : In-situ moisture content much lower than optimum moisture content. Gauge Serial No. :38069
11/21/2025 3 16.1 97.2 2025-051 106.4 19.3 91.4 95 D6938 Fail
Location : Building #14, Elv/Depth :2 feet below finished grade
Comment : Recompaction required. Gauge Serial No. :38069
11/21/2025 4 13.8 95.9 2025-051 106.4 19.3 90.1 95 D6938 Fail
Location : Building #14, Elv/Depth :2 feet below finished grade
Comment : Recompaction required. Gauge Serial No. :38069
11/21/2025 5 13.6 96.4 2025-051 106.4 19.3 90.6 95 D6938 Fail
Location : Building #14, Elv/Depth :2 feet below finished grade
Comment : Recompaction required. Gauge Serial No. :38069
11/21/2025 6 15.2 104.7 2025-051 106.4 19.3 98.4 95 D6938 Pass
Location : Building #14 (retest), Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :38069
11/21/2025 7 16 102.5 2025-051 106.4 19.3 96.3 95 D6938 Pass
Location : Building #14 (retest), Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :38069
Technician Signature / DateSamara Simha Reddy Kandi, November 21, 2025
Reviewer Name / DateKenneth Mosman, November 25, 2025