Date :12/23/2025
Project No :2025C211
Client Company :Pulte
Arrival Time :12/23/2025 07:30
Onsite Hours :02:30
Name of the Project :Haley's Bluff - Philadelphia Rd.
Project Location :Jasper
Weather :Sunny
Departure Time :12/23/2025 10:00
ASEC Technician Name :Sean Willett

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
12/23/2025 1 17.4 101.5 FP 2 100.0 18.5 101.5 98 D6938 Pass
Location : Storm line B-7 by entrance, Elv/Depth :at finished grade
Comment : Gauge Serial No. :77-19952
Technician Signature / DateSean Willett, December 23, 2025
Reviewer Name / DateKenneth Mosman, February 02, 2026