Skip to content

Density Test Report

Date :12/30/2025
Project No :2025C260
Client Company :Artisan
Arrival Time :12/30/2025 09:30
Onsite Hours :06:00
Name of the Project :NW (PHASE 2) Parkway Extension
Project Location :Dallas
Weather :sunny
Departure Time :12/30/2025 15:30
ASEC Technician Name :Clyde Smith

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
12/30/2025 1 14.6 99.7 2025-033 SP 104.0 16.2 95.9 95 D6938 Pass
Location : Cul de sac basement lots, Elv/Depth :872
Comment : Gauge Serial No. :91643
12/30/2025 2 14.1 102.0 2025-033 SP 104.0 16.2 98.1 95 D6938 Pass
Location : Cul de sac basement lots, Elv/Depth :874
Comment : Gauge Serial No. :91643
12/30/2025 3 12.1 105.4 2025-035 SP 107.8 13.0 97.8 95 D6938 Pass
Location : Cul de sac basement lots, Elv/Depth :874
Comment : Gauge Serial No. :91643
12/30/2025 4 13.9 101.5 2025-033 SP 104.0 16.2 97.6 95 D6938 Pass
Location : Cul de sac basement lots, Elv/Depth :874
Comment : Gauge Serial No. :91643
Technician Signature / DateClyde Smith, December 30, 2025
Reviewer Name / DateKenneth Mosman, January 30, 2026