Skip to content

Density Test Report

Date :12/30/2025
Project No :2025C211
Client Company :Pulte
Arrival Time :12/30/2025 07:30
Onsite Hours :05:00
Name of the Project :Haley's Bluff - Philadelphia Rd.
Project Location :Jasper
Weather :Sunny
Departure Time :12/30/2025 12:30
ASEC Technician Name :Sean Willett

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
12/30/2025 1 14.6 105.2 2025-055 107.3 15.5 98.0 95 D6938 Pass
Location : Lot #16, Elv/Depth :1468-69
Comment : Gauge Serial No. :77-19952
12/30/2025 2 16.0 96.7 FP 2 100.0 18.5 96.7 95 D6938 Pass
Location : Lot #19, Elv/Depth :1468-69
Comment : Gauge Serial No. :77-19952
Technician Signature / DateSean Willett, December 30, 2025
Reviewer Name / DateKenneth Mosman, February 02, 2026