- Home
- Density Test Report Report ID: 88942
- Edit Download Report
Density Test Report
Date :12/31/2025
Project No :2025C211
Client Company :Pulte
Arrival Time :12/31/2025 07:30
Onsite Hours :07:30
Name of the Project :Haley's Bluff - Philadelphia Rd.
Project Location :Jasper
Weather :Sunny
Departure Time :12/31/2025 15:00
ASEC Technician Name :Sean Willett
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 12/31/2025 | 1 | 17.8 | 99.9 | FP 2 | 100.0 | 18.5 | 99.9 | 95 | D6938 | Pass |
| Location : | Lot #15, Elv/Depth :1471 | |||||||||
| Comment : | Gauge Serial No. :77-19952 | |||||||||
| 12/31/2025 | 2 | 15.0 | 93.8 | FP 2 | 100.0 | 18.5 | 93.8 | D6938 | Pass | |
| Location : | Lot #17, Elv/Depth :1471 | |||||||||
| Comment : | will retest | Gauge Serial No. :77-19952 | ||||||||
| 12/31/2025 | 3 | 20.5 | 85.0 | FP 2 | 100.0 | 18.5 | 85.0 | 95 | D6938 | Fail |
| Location : | Lot #19, Elv/Depth :1471 | |||||||||
| Comment : | will retest | Gauge Serial No. :77-19952 | ||||||||
| 12/31/2025 | 4 | 17.0 | 90.9 | FP 2 | 100.0 | 18.5 | 90.9 | 95 | D6938 | Fail |
| Location : | Lot #17 retest, Elv/Depth :1471 | |||||||||
| Comment : | will retest | Gauge Serial No. :77-19952 | ||||||||
| 12/31/2025 | 5 | 17.0 | 97.1 | FP 2 | 100.0 | 18.5 | 97.1 | 95 | D6938 | Pass |
| Location : | Lot #19 retest, Elv/Depth :1471 | |||||||||
| Comment : | Gauge Serial No. :77-19952 | |||||||||
| 12/31/2025 | 6 | 15.3 | 103.2 | 2025-055 | 107.3 | 15.5 | 96.2 | 95 | D6938 | Pass |
| Location : | Lot #17 retest, Elv/Depth :1471 | |||||||||
| Comment : | Gauge Serial No. :77-19952 | |||||||||
Technician Signature / DateSean Willett, December 31, 2025
Reviewer Name / DateKenneth Mosman, February 02, 2026