Skip to content

Density Test Report

Date :12/31/2025
Project No :2025C260
Client Company :Artisan
Arrival Time :12/31/2025 09:00
Onsite Hours :06:00
Name of the Project :NW (PHASE 2) Parkway Extension
Project Location :Dallas
Weather :cloudy
Departure Time :12/31/2025 15:00
ASEC Technician Name :Clyde Smith

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
12/31/2025 1 12.1 104.0 2025-035 SP 107.8 13.0 96.5 95 D6938 Pass
Location : Cul de sac building lots, Elv/Depth :875
Comment : Gauge Serial No. :91643
12/31/2025 2 14.1 98.7 2025-033 SP 104.0 16.2 94.9 95 D6938 Fail
Location : Cul de sac, Elv/Depth :876
Comment : Gauge Serial No. :91643
12/31/2025 3 13.6 101.7 2025-033 SP 104.0 16.2 97.8 95 D6938 Pass
Location : Cul de sac building lots, Elv/Depth :876
Comment : Gauge Serial No. :91643
12/31/2025 4 13.7 100.9 2025-033 SP 104.0 16.2 97.0 95 D6938 Pass
Location : Cul de sac building lots, Elv/Depth :876
Comment : Gauge Serial No. :91643
Technician Signature / DateClyde Smith, December 31, 2025
Reviewer Name / DateKenneth Mosman, January 30, 2026