- Home
- Density Test Report Report ID: 89041
- Edit Download Report
Density Test Report
Date :01/08/2026
Project No :2025C260
Client Company :Artisan
Arrival Time :01/08/2026 08:00
Onsite Hours :9:00
Name of the Project :NW (PHASE 2) Parkway Extension
Project Location :Dallas
Weather :cloudy
Departure Time :01/08/2026 17:00
ASEC Technician Name :Clyde Smith
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 01/08/2026 | 1 | 13.3 | 102.7 | 2025-035 SP | 107.8 | 13.0 | 95.3 | 95 | D6938 | Pass |
| Location : | Building lots at cul-de-sac, Elv/Depth :881 | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 01/08/2026 | 2 | 11.5 | 103.2 | 2025-035 SP | 107.8 | 13.0 | 95.7 | 95 | D6938 | Pass |
| Location : | Building lots at cul-de-sac, Elv/Depth :883 | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 01/08/2026 | 3 | 12.2 | 103.3 | 2025-035 SP | 107.8 | 13.0 | 95.8 | 95 | D6938 | Pass |
| Location : | Building lots at cul-de-sac, Elv/Depth :885 | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
Technician Signature / DateClyde Smith, January 8, 2026
Reviewer Name / DateKenneth Mosman, January 09, 2026