Skip to content

Density Test Report

Date :01/07/2026
Project No :2025C244
Client Company :McCallan Group
Arrival Time :01/07/2026 07:45
Onsite Hours :10:15
Name of the Project :Cassville Rd tract, proposed Burrito Wrap
Project Location :Cartersville
Weather :cloudy
Departure Time :01/07/2026 18:00
ASEC Technician Name :Samara Simha Reddy Kandi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
01/07/2026 1 26.4 94.3 2025-050 103.5 21.4 91.1 95 D2937 Fail
Location : Lot #90, Elv/Depth :After 3 lifts
Comment : This area requires scarification, aeration to lower moisture contents then recompacted prior to retesting.
Technician Signature / DateSamara Simha Reddy Kandi, January 7, 2026
Reviewer Name / DateKenneth Mosman, February 16, 2026