Skip to content

Density Test Report

Date :01/09/2026
Project No :2025C281
Client Company :SR Homes
Arrival Time :01/09/2026 07:00
Onsite Hours :02:00
Name of the Project :Owen Mills - Owens Store Rd
Project Location :Canton
Weather :Overcast
Departure Time :01/09/2026 09:00
ASEC Technician Name :Sean Willett

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
01/09/2026 1 15.9 101.0 2026-001 (on site cut) 99.1 20.1 101.9 95 D6938 Pass
Location : dam right side, Elv/Depth :final
Comment : Lab proctor 2025-52 101.1 @ 22.6% Gauge Serial No. :77-19952
01/09/2026 2 15.5 99.7 2026-001 (on site cut) 99.1 20.1 100.6 95 D6938 Pass
Location : dam middle, Elv/Depth :final
Comment : Lab proctor 2025-52 101.1 @ 22.6% Gauge Serial No. :77-19952
01/09/2026 3 16.5 100.3 2026-001 (on site cut) 99.1 20.1 101.2 95 D6938 Pass
Location : dam right side, Elv/Depth :final
Comment : Lab proctor 2025-52 101.1 @ 22.6% Gauge Serial No. :77-19952
Technician Signature / DateSean Willett, January 9, 2026
Reviewer Name / DateRamchandra Mogulla, January 30, 2026