Skip to content

Density Test Report

Date :01/15/2026
Project No :2026C103
Client Company :Artisan
Arrival Time :01/15/2026 09:00
Onsite Hours :07:30
Name of the Project :NW PH 2, UNIT 4
Project Location :Dallas
Weather :Sunny cold
Departure Time :01/15/2026 16:30
ASEC Technician Name :Clyde Smith

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
01/15/2026 1 14.8 101.2 2025-033 SP 104.0 16.2 97.3 95 D6938 Pass
Location : Building Lot #39, Elv/Depth :8 feet below finished grade
Comment : Gauge Serial No. :91643
01/15/2026 2 15.6 100.3 2025-033 SP 104.0 16.2 96.4 95 D6938 Pass
Location : Building Lot #38, Elv/Depth :9 feet below finished grade
Comment : Gauge Serial No. :91643
01/15/2026 3 14.1 99.8 2025-033 SP 104.0 16.2 96.0 95 D6938 Pass
Location : Building Lot #37, Elv/Depth :8 feet below finished grade
Comment : Gauge Serial No. :91643
01/15/2026 4 15.4 100.7 2025-033 SP 104.0 16.2 96.8 95 D6938 Pass
Location : Building Lot #40, Elv/Depth :7 feet below finished grade
Comment : Gauge Serial No. :91643
01/15/2026 5 16.5 102.3 2025-033 SP 104.0 16.2 98.4 95 D6938 Pass
Location : Building Lot #56, Elv/Depth :14 feet below finished grade
Comment : Gauge Serial No. :91643
01/15/2026 6 16.9 103.0 2025-033 SP 104.0 16.2 99.0 95 D6938 Pass
Location : Building Lot #56, Elv/Depth :14 feet below finished grade
Comment : Gauge Serial No. :91643
Technician Signature / DateClyde Smith, January 15, 2026
Reviewer Name / DateKenneth Mosman, February 04, 2026