Density Test Report

Date :01/28/2026
Project No :2025C211
Client Company :Pulte
Arrival Time :01/28/2026 08:30
Onsite Hours :07:30
Name of the Project :Haley's Bluff - Philadelphia Rd.
Project Location :Jasper
Weather :Sunny
Departure Time :01/28/2026 16:00
ASEC Technician Name :Sean Willett

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
01/28/2026 1 20.7 87.9 FP 2 100.0 18.5 87.9 95 D6938 Fail
Location : Retaining wall #5, Elv/Depth :8 baskets
Comment : will retest Gauge Serial No. :77-19952
01/28/2026 2 18.2 89.8 FP 2 100.0 18.5 89.8 95 D6938 Fail
Location : Retaining wall #5, Elv/Depth :8 baskets
Comment : will retest Gauge Serial No. :77-19952
01/28/2026 3 22.4 77.7 FP 2 100.0 18.5 77.7 95 D6938 Fail
Location : Retaining wall #5, Elv/Depth :8 baskets
Comment : contractor placed too thick of a lift. they are cutting it down and recompacting. will retest. Gauge Serial No. :77-19952
01/28/2026 4 21.2 89.4 FP 2 100.0 18.5 89.4 95 D6938 Fail
Location : Retaining wall #5, Elv/Depth :8 baskets
Comment : will retest Gauge Serial No. :77-19952
01/28/2026 5 17.5 95.1 FP 2 100.0 18.5 95.1 95 D6938 Pass
Location : Retaining wall #5, Elv/Depth :8 baskets
Comment : Gauge Serial No. :77-19952
01/28/2026 6 19.4 89.2 FP 2 100.0 18.5 89.2 95 D6938 Fail
Location : Retaining wall #5, Elv/Depth :8 baskets
Comment : will retest Gauge Serial No. :77-19952
01/28/2026 7 18.6 87.9 FP 2 100.0 18.5 87.9 95 D6938 Fail
Location : Retaining wall #5, Elv/Depth :8 baskets
Comment : will retest Gauge Serial No. :77-19952
01/28/2026 8 21.2 87.6 FP 2 100.0 18.5 87.6 95 D6938 Fail
Location : Retaining wall #5, Elv/Depth :8 baskets
Comment : will retest Gauge Serial No. :77-19952
01/28/2026 9 20.1 90.5 FP 2 100.0 18.5 90.5 95 D6938 Fail
Location : Retaining wall #5, Elv/Depth :8 baskets
Comment : will retest Gauge Serial No. :77-19952
01/28/2026 10 23.0 117.6 FP 3 100.5 20.5 95.1 95 D6938 Pass
Location : Retaining wall #5, Elv/Depth :8 baskets
Comment : Gauge Serial No. :77-19952
01/28/2026 11 17.0 97.8 FP 2 100.0 18.5 97.8 95 D6938 Pass
Location : Retaining wall #5, Elv/Depth :9 baskets
Comment : Gauge Serial No. :77-19952
01/28/2026 12 18.5 93.2 FP 2 100.0 18.5 93.2 95 D6938 Fail
Location : Retaining wall #5, Elv/Depth :9 baskets
Comment : will retest Gauge Serial No. :77-19952
01/28/2026 13 16.1 100.9 FP 2 100.0 18.5 100.9 95 D6938 Pass
Location : Retaining wall #5, Elv/Depth :9 baskets
Comment : Gauge Serial No. :77-19952
Technician Signature / DateSean Willett, January 28, 2026
Reviewer Name / DateKenneth Mosman, February 18, 2026