Skip to content

Density Test Report

Date :01/30/2026
Project No :2025C211
Client Company :Pulte
Arrival Time :01/30/2026 07:30
Onsite Hours :06:30
Name of the Project :Haley's Bluff - Philadelphia Rd.
Project Location :Jasper
Weather :Sunny
Departure Time :01/30/2026 14:00
ASEC Technician Name :Sean Willett

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
01/30/2026 1 23.0 96.7 FP 3 100.5 20.5 96.2 95 D6938 Pass
Location : Lot #44 and #96-97 deep fill, Elv/Depth :1487
Comment : Gauge Serial No. :77-19952
01/30/2026 2 19.4 96.2 FP 3 100.5 20.5 95.7 95 D6938 Pass
Location : Lot #44 and #96-97, Elv/Depth :1487
Comment : Gauge Serial No. :77-19952
01/30/2026 3 19.9 92.1 FP 2 100.0 18.5 92.1 95 D6938 Fail
Location : aa-7 to aa-8 pipeline, Elv/Depth :final
Comment : contractor will recompact on a later date Gauge Serial No. :77-19952
01/30/2026 4 20.1 91.6 FP 2 100.0 18.5 91.6 95 D6938 Fail
Location : aa-7 to aa-8 pipeline, Elv/Depth :final
Comment : contractor will recompact on a later date Gauge Serial No. :77-19952
01/30/2026 5 22.3 92.9 FP 2 100.0 18.5 92.9 956 D6938 Fail
Location : Retaining wall #5, Elv/Depth :13 baskets
Comment : Gauge Serial No. :77-19952
01/30/2026 6 12.8 95.9 FP 2 100.0 18.5 95.9 95 D6938 Pass
Location : Retaining wall #5, Elv/Depth :13 baskets
Comment : Gauge Serial No. :77-19952
01/30/2026 7 19.6 122.1 FP 2 100.0 18.5 122.1 95 D6938 Pass
Location : Retaining wall #5, Elv/Depth :13 baskets
Comment : Gauge Serial No. :77-19952
01/30/2026 8 17.5 92.1 FP 2 100.0 18.5 92.1 95 D6938 Fail
Location : Retaining wall #5, Elv/Depth :14 baskets
Comment : Gauge Serial No. :77-19952
01/30/2026 9 19.3 93.3 FP 2 100.0 18.5 93.3 95 D6938 Fail
Location : Retaining wall #5, Elv/Depth :14 baskets
Comment : Gauge Serial No. :77-19952
01/30/2026 11 18.6 95.2 FP 2 100.0 18.5 95.2 95 D6938 Pass
Location : Retaining wall #5, Elv/Depth :14 baskets
Comment : Gauge Serial No. :77-19952
01/30/2026 12 12.5 95.4 FP 2 100.0 18.5 95.4 95 D6938 Pass
Location : Retaining wall #5, Elv/Depth :14 baskets
Comment : Gauge Serial No. :77-19952
01/30/2026 13 15.8 93.5 FP 2 100.0 18.5 93.5 95 D6938 Fail
Location : Lot #44 and #96-97 deep fill, Elv/Depth :1489-1490
Comment : Gauge Serial No. :77-19952
01/30/2026 14 13.6 100.1 FP 2 100.0 18.5 100.1 95 D6938 Pass
Location : Lot #44 and #96-97 deep fill, Elv/Depth :1489-1490
Comment : Gauge Serial No. :77-19952
01/30/2026 15 15.4 95.1 FP 2 100.0 18.5 95.1 95 D6938 Pass
Location : Lot #44 and #96-97 deep fill, Elv/Depth :1489-1490
Comment : Gauge Serial No. :77-19952
01/30/2026 16 20.0 93.8 FP 2 100.0 18.5 93.8 95 D6938 Fail
Location : Retaining wall #5, Elv/Depth :15 baskets
Comment : Gauge Serial No. :77-19952
01/30/2026 17 21.5 89.1 FP 2 100.0 18.5 89.1 95 D6938 Fail
Location : Retaining wall #5, Elv/Depth :15 baskets
Comment : Gauge Serial No. :77-19952
01/30/2026 18 20.9 92.6 FP 2 100.0 18.5 92.6 95 D6938 Fail
Location : Retaining wall #5, Elv/Depth :15 baskets
Comment : Gauge Serial No. :77-19952
01/30/2026 19 18.7 97.3 FP 2 100.0 18.5 97.3 95 D6938 Pass
Location : Retaining wall #5, Elv/Depth :15 baskets
Comment : Gauge Serial No. :77-19952
01/30/2026 20 21.5 98.2 FP 2 100.0 18.5 98.2 95 D6938 Pass
Location : Retaining wall #5, Elv/Depth :15 baskets
Comment : Gauge Serial No. :77-19952
01/30/2026 21 19.2 99.7 FP 2 100.0 18.5 99.7 98 D6938 Pass
Location : Decel lane, Elv/Depth :at finished grade
Comment : Gauge Serial No. :77-19952
01/30/2026 22 19.8 103.0 FP 2 100.0 18.5 103.0 98 D6938 Pass
Location : Decel lane, Elv/Depth :at finished grade
Comment : Gauge Serial No. :77-19952
01/30/2026 23 18.9 100.0 FP 2 100.0 18.5 100.0 98 D6938 Pass
Location : Decel lane, Elv/Depth :at finished grade
Comment : Gauge Serial No. :77-19952
01/30/2026 24 17.1 95.9 FP 2 100.0 18.5 95.9 95 D6938 Pass
Location : Retaining wall #5, Elv/Depth :16 baskets
Comment : Gauge Serial No. :77-19952
01/30/2026 25 13.3 99.3 FP 2 100.0 18.5 99.3 95 D6938 Pass
Location : Retaining wall #5, Elv/Depth :16 baskets
Comment : Gauge Serial No. :77-19952
01/30/2026 26 17.4 96.3 FP 2 100.0 18.5 96.3 95 D6938 Pass
Location : Retaining wall #5 , Elv/Depth :17 baskets
Comment : Gauge Serial No. :77-19952
Technician Signature / DateSean Willett, January 30, 2026
Reviewer Name / DateKenneth Mosman, February 18, 2026