- Home
- Density Test Report Report ID: 89949
- Edit Download Report
Density Test Report
Date :02/03/2026
Project No :2026C103
Client Company :Artisan
Arrival Time :02/03/2026 08:00
Onsite Hours :9:30
Name of the Project :NW PH 2, UNIT 4
Project Location :Dallas
Weather :cloudy
Departure Time :02/03/2026 17:30
ASEC Technician Name :Clyde Smith
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 02/03/2026 | 1 | 15.2 | 102.7 | 2025-036 SP | 107.0 | 18.5 | 96.0 | 95 | D6938 | Pass |
| Location : | Building Lots #38 thru 36, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 02/03/2026 | 2 | 16.2 | 102.6 | 2025-036 SP | 107.0 | 18.5 | 95.9 | 95 | D6938 | Pass |
| Location : | Building Lots #38 thru 36, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 02/03/2026 | 3 | 16.9 | 103.0 | 2025-036 SP | 107.0 | 18.5 | 96.3 | 95 | D6938 | Pass |
| Location : | Building Lots #38 thru 36, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 02/03/2026 | 4 | 17.1 | 105.4 | 2025-036 SP | 107.0 | 18.5 | 98.5 | 98 | D6938 | Pass |
| Location : | Building Lots #38 thru 36, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 02/03/2026 | 5 | 15.9 | 106.4 | 2025-036 SP | 107.0 | 18.5 | 99.4 | 98 | D6938 | Pass |
| Location : | Building Lots #38 thru 36, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 02/03/2026 | 6 | 17.2 | 107.1 | 2025-036 SP | 107.0 | 18.5 | 100.1 | D6938 | Pass | |
| Location : | Building Lots #38 thru 36, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 02/03/2026 | 7 | 13.7 | 102.6 | 2025-033 SP | 104.0 | 16.2 | 98.7 | 95 | D6938 | Pass |
| Location : | Building Lots #32 thru 34 , Elv/Depth :3 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 02/03/2026 | 8 | 14.2 | 102.7 | 2025-033 SP | 104.0 | 16.2 | 98.8 | 98 | D6938 | Pass |
| Location : | Building Lots #32 thru 34, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 02/03/2026 | 9 | 14.6 | 102.7 | 2025-033 SP | 104.0 | 16.2 | 98.8 | D6938 | Pass | |
| Location : | Building Lots #32 thru 34, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 02/03/2026 | 10 | 16.6 | 97.7 | Field proctor #6 | 98.0 | 17.2 | 99.7 | 95 | D6938 | Pass |
| Location : | Building Lot #56, Elv/Depth : 866 | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 02/03/2026 | 11 | 15.1 | 99.0 | Field proctor #6 | 98.0 | 17.2 | 101.0 | 95 | D6938 | Pass |
| Location : | Building Lot #56, Elv/Depth :867 | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
Technician Signature / DateClyde Smith, February 3, 2026
Reviewer Name / DateKenneth Mosman, February 16, 2026