Density Test Report
Date :02/06/2026
Project No :2026C103
Client Company :Artisan
Arrival Time :02/06/2026 08:00
Onsite Hours :9:30
Name of the Project :NW PH 2, UNIT 4
Project Location :Dallas
Weather :sunny
Departure Time :02/06/2026 17:30
ASEC Technician Name :Clyde Smith
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 02/06/2026 | 1 | 15.9 | 97.0 | Field proctor #6 | 98.0 | 17.2 | 99.0 | 95 | D6938 | Pass |
| Location : | Building Lots #61 and 62, Elv/Depth :884 | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 02/06/2026 | 2 | 16.8 | 96.1 | Field proctor #6 | 98.0 | 17.2 | 98.1 | 95 | D6938 | Pass |
| Location : | Building Lots #61 and 62, Elv/Depth :884 | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 02/06/2026 | 3 | 12.2 | 105.1 | 2025-035 SP | 107.8 | 13.0 | 97.5 | D6938 | Pass | |
| Location : | Building Lots #61 and 62 , Elv/Depth :885 | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 02/06/2026 | 4 | 15.4 | 96.9 | Field proctor #6 | 98.0 | 17.2 | 98.9 | 95 | D6938 | Pass |
| Location : | Building Lots #57 and 58, Elv/Depth :875 | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 02/06/2026 | 5 | 15.9 | 101.1 | 2025-033 SP | 104.0 | 16.2 | 97.2 | 95 | D6938 | Pass |
| Location : | Building Lots #57 and 58, Elv/Depth :876 | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
Technician Signature / DateClyde Smith, February 6, 2026
Reviewer Name / DateKenneth Mosman, February 18, 2026