Skip to content

Density Test Report

Date :02/09/2026
Project No :2026C103
Client Company :Artisan
Arrival Time :02/09/2026 08:00
Onsite Hours :9:30
Name of the Project :NW PH 2, UNIT 4
Project Location :Dallas
Weather :sunny
Departure Time :02/09/2026 17:30
ASEC Technician Name :Clyde Smith

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
02/09/2026 1 15.8 96.5 Field proctor #6 98.0 17.2 98.5 95 D6938 Pass
Location : Building Lots #65 and 66, Elv/Depth :20 feet below finished grade
Comment : Gauge Serial No. :91643
02/09/2026 2 14.7 96.7 Field proctor #6 98.0 17.2 98.7 95 D6938 Pass
Location : Building Lots #65 and 66, Elv/Depth :20 feet below finished grade
Comment : Gauge Serial No. :91643
02/09/2026 3 14.9 95.9 Field proctor #6 98.0 17.2 97.9 95 D6938 Pass
Location : Building Lots #65 and 66, Elv/Depth :18 feet below finished grade
Comment : Gauge Serial No. :91643
Technician Signature / DateClyde Smith, February 9, 2026
Reviewer Name / DateKenneth Mosman, February 23, 2026