Density Test Report
Date :02/17/2026
Project No :2025C215
Client Company :Artisan
Arrival Time :02/17/2026 09:00
Onsite Hours :9:00
Name of the Project :NW Unit 4 Parkway Ext. Phase 1
Project Location :Dallas
Weather :sunny
Departure Time :02/17/2026 18:00
ASEC Technician Name :Clyde Smith
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 02/17/2026 | 1 | 13.3 | 103.4 | 2025-035 SP | 107.8 | 13.0 | 95.9 | 95 | D6938 | Pass |
| Location : | 18" RCP storm line between D13 and D20, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 02/17/2026 | 2 | 12.8 | 104.8 | 2025-035 SP | 107.8 | 13.0 | 97.2 | 95 | D6938 | Pass |
| Location : | 18" RCP storm line between D13 and D20, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 02/17/2026 | 3 | 12.1 | 118.7 | 2025-035 SP | 107.8 | 13.0 | 98.2 | 95 | D6938 | Pass |
| Location : | 18" RCP storm line between D13 and D20, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 02/17/2026 | 4 | 14.2 | 120.9 | 2025-035 SP | 107.8 | 13.0 | 98.2 | 95 | D6938 | Pass |
| Location : | 18" RCP storm line between D13 and D20, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
Technician Signature / DateClyde Smith, February 17, 2026
Reviewer Name / DateKenneth Mosman, February 23, 2026