- Home
- Density Test Report Report ID: 90547
- Edit Download Report
Density Test Report
Date :02/23/2026
Project No :2026C101
Client Company :Artisan
Arrival Time :02/23/2026 11:30
Onsite Hours :03:00
Name of the Project :Seven Hills PHASE 13, UNIT 4 Lots
Project Location :Dallas
Weather :sunny cold
Departure Time :02/23/2026 14:30
ASEC Technician Name :Clyde Smith
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 02/23/2026 | 1 | 15.4 | 95.7 | Field proctor #6 | 98.0 | 17.2 | 97.7 | 95 | D6938 | Pass |
| Location : | Building Lot #40, Elv/Depth :10 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 02/23/2026 | 2 | 14.3 | 95.7 | Field proctor #6 | 98.0 | 17.2 | 97.7 | 95 | D6938 | Pass |
| Location : | Building Lot #40, Elv/Depth :10 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 02/23/2026 | 3 | 14.4 | 94.9 | Field proctor #6 | 98.0 | 17.2 | 96.8 | 95 | D6938 | Pass |
| Location : | Building Lot #41, Elv/Depth :10 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 02/23/2026 | 4 | 14.7 | 94.7 | Field proctor #6 | 98.0 | 17.2 | 96.6 | 95 | D6938 | Pass |
| Location : | Building Lot #41, Elv/Depth :10 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
Technician Signature / DateClyde Smith, February 23, 2026
Reviewer Name / DateKenneth Mosman, February 26, 2026