Skip to content

Density Test Report

Date :02/25/2026
Project No :2025C269
Client Company :Lewis Contracting
Arrival Time : 13:00
Onsite Hours :
Name of the Project :Main St. & First Ave. - Mixed-use
Project Location :Lilburn
Weather :Partly Cloudy
Departure Time : 17:00
ASEC Technician Name :Jamiries Johnson

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
02/25/2026 1 19.7 85.1 2025-059 88.7 22.0 95.9 95 D2937 Pass
Location : S3-S2, Elv/Depth :3 feet below finished grade
Comment :
02/25/2026 2 20.8 92.5 2025-058 95.2 18.6 97.2 95 D2937 Pass
Location : A1-G1, Elv/Depth :3 feet below finished grade
Comment :
Technician Signature / DateJamiries Johnson, February 25, 2026
Reviewer Name / DateKenneth Mosman, March 04, 2026