Skip to content

Density Test Report

Date :02/20/2026
Project No :2025C269
Client Company :Lewis Contracting
Arrival Time :02/20/2026 11:00
Onsite Hours :06:00
Name of the Project :Main St. & First Ave. - Mixed-use
Project Location :Lilburn
Weather :sunny
Departure Time :02/20/2026 17:00
ASEC Technician Name :Mahendra Mylabathula

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
02/20/2026 1 18 98.9 2026-010 98.1 22.4 100.8 95 D6938 Pass
Location : S line, Elv/Depth :at finished grade
Comment : Gauge Serial No. :38069
02/20/2026 2 23.6 94.9 2025-058 95.2 18.6 99.7 95 D6938 Pass
Location : S line, Elv/Depth :at finished grade
Comment : Gauge Serial No. :38069
02/20/2026 3 25 90.4 2025-057 92.1 25.7 98.2 95 D6938 Pass
Location : A Line, Elv/Depth :at finished grade
Comment : Gauge Serial No. :38069
02/20/2026 4 26.4 90.8 2025-057 92.1 25.7 98.6 95 D6938 Pass
Location : A Line, Elv/Depth :at finished grade
Comment : Gauge Serial No. :38069
02/20/2026 5 21.8 85.7 2025-057 92.1 25.7 93.1 95 D6938 Fail
Location : A Line, Elv/Depth :at finished grade
Comment : Gauge Serial No. :38069
Technician Signature / DateMahendra Mylabathula, February 20, 2026
Reviewer Name / DateKenneth Mosman, March 04, 2026