- Density Test Report Report ID: 91335
- Edit Download Report
Density Test Report
Date :03/18/2026
Project No :2026C103
Client Company :Artisan
Arrival Time :03/18/2026 08:00
Onsite Hours :9:30
Name of the Project :NW PH 2, UNIT 4
Project Location :Dallas
Weather :sunny
Departure Time :03/18/2026 17:30
ASEC Technician Name :Clyde Smith
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 03/18/2026 | 1 | 15.7 | 95.6 | Field proctor #6 | 98.0 | 17.2 | 97.6 | 95 | D6938 | Pass |
| Location : | 8" sanitary sewer trench between B9 and B11, Elv/Depth :6 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 03/18/2026 | 2 | 15.9 | 95.1 | Field proctor #6 | 98.0 | 17.2 | 97.0 | 95 | D6938 | Pass |
| Location : | 8" sanitary sewer trench between B9 and B11, Elv/Depth :6 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 03/18/2026 | 3 | 13.7 | 101.4 | 2025-033 SP | 104.0 | 16.2 | 97.5 | 95 | D6938 | Pass |
| Location : | 8"sanitary sewer trench between B9 and B11, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 03/18/2026 | 4 | 15.8 | 96.2 | Field proctor #6 | 98.0 | 17.2 | 98.2 | 95 | D6938 | Pass |
| Location : | 8" sanitary sewer trench between B9 and B11, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 03/18/2026 | 5 | 14.6 | 101.6 | 2025-033 SP | 104.0 | 16.2 | 97.7 | 98 | D6938 | Fail |
| Location : | 8" sanitary sewer trench between B9 and B11, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 03/18/2026 | 6 | 13.6 | 96.7 | Field proctor #6 | 98.0 | 17.2 | 98.7 | 98 | D6938 | Pass |
| Location : | 8" sanitary sewer trench between B9 and B11, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
Technician Signature / DateClyde Smith, March 18, 2026
Reviewer Name / DateKenneth Mosman, March 19, 2026