Concrete Test Report

Date :03/23/2026
Project No :2026C115-WO 1
Client Company :WSP
Arrival Time :
Onsite Hours :
Name of the Project :Lanier Islands Parkway
Project Location :Buford
Weather :
Departure Time :
ASEC Technician Name :Mahendra Mylabathula

Concrete Placement Information

Location(S): N/A
Testing: 1 Set of concrete specimens (5 per set) were cast during the cast-in-place concrete pour at the above referenced location, in accordance with ASTM C31. The specimen will remain on site for the initial 24-48 hrs curing.
Compliance:

Field placement of concrete appeared to be in accordance with the project specifications (i.e., slump, temperature, etc) (refer to remarks below)

Deviations and/or noncompliances were noted during the field placement (refer to remarks below)

Specimen
Pick Up:
1 Sets of concrete specimens/ 5 specimen per set were picked up & transported to AS Engineering and Consulting LLC (ASEC) for curing and testing in accordance with ASTM C39, C670/1231
Field Curing: Specimen were stored for the initial 24 hours.
Near the poured structure
In an insulated curing box
Other
Remarks:

Field Test Data

Specimen Type Selection : Cylinder

Set Number :A
Date Sampled :03/23/2026
Sampled By :Mahendra Mylabathula
Contractor :CONLAN COMPANY
Truck Number :1
Time Batched :N/A
Location of Placement :F2
Number of samples cast :5
Ambient Temperature (°f) :N/A
Slump (in.) :6
Water added (gal.) :N/A
Laboratory Number :2026-067
Time Sampled :04:00
Weather Condition :N/A
Concrete Supplier :MORGAN
Mix ID :4000 57-89 SOG NA
Quantity of Load (cu. yd.) :10
Sample Cast :1
Specified Strength :4000
Concrete Temperature(°f) :70
Air Content (%) :3
Unit Weight (pcf) :148.8

Strength Test Results

Specimen Number Scheduled Test Date Date Tested Age (days) Dia(in.) Area (sq in.) Maximum Loads (lbf) Strength (lbs) % Design Strength Type of Fracture
1 03/30/2026 03/30/2026 7 4.00 12.57 51338 4080 102.0 Type 2
2 04/20/2026 N/A
3 04/20/2026 N/A
4 04/20/2026 N/A
5 05/18/2026 N/A

UNLESS OTHERWISE SPECIFIED, TESTS WERE PERFORMED IN ACCORDANCE WITH ASTM TEST METHODS C31, C39, C138, C143, C173, AND C1064. FRACTURE TYPE INDICATED BY NUMBER.

(Type 1) Cone (Type 2) Cone-split (Type 3) Vertical (Type 4) Shear (Type 5) Edge Fracture (Type 6) Pointed

Field Test Data

Specimen Type Selection : Cylinder

Set Number :B
Date Sampled :03/23/2026
Sampled By :Mahendra Mylabathula
Contractor :COLMAN
Truck Number :11
Time Batched :N/A
Location of Placement :F8
Number of samples cast :5
Ambient Temperature (°f) :N/A
Slump (in.) :6
Water added (gal.) :N/A
Laboratory Number :2026-067
Time Sampled :5
Weather Condition :N/A
Concrete Supplier :MORGAN
Mix ID :4000 57-89 SOG NA
Quantity of Load (cu. yd.) :10
Sample Cast :1
Specified Strength :4000
Concrete Temperature(°f) :75
Air Content (%) :2.5
Unit Weight (pcf) :147.5

Strength Test Results

Specimen Number Scheduled Test Date Date Tested Age (days) Dia(in.) Area (sq in.) Maximum Loads (lbf) Strength (lbs) % Design Strength Type of Fracture

UNLESS OTHERWISE SPECIFIED, TESTS WERE PERFORMED IN ACCORDANCE WITH ASTM TEST METHODS C31, C39, C138, C143, C173, AND C1064. FRACTURE TYPE INDICATED BY NUMBER.

(Type 1) Cone (Type 2) Cone-split (Type 3) Vertical (Type 4) Shear (Type 5) Edge Fracture (Type 6) Pointed

Field Test Data

Specimen Type Selection : Cylinder

Set Number :C
Date Sampled :03/23/2026
Sampled By :Mahendra Mylabathula
Contractor :COLMAN
Truck Number :21
Time Batched :N/A
Location of Placement :F16
Number of samples cast :5
Ambient Temperature (°f) :N/A
Slump (in.) :5
Water added (gal.) :N/A
Laboratory Number :2026-067
Time Sampled :6
Weather Condition :N/A
Concrete Supplier :MORGAN
Mix ID :4000 57-89 SOG NA
Quantity of Load (cu. yd.) :10
Sample Cast :1
Specified Strength :4000
Concrete Temperature(°f) :70
Air Content (%) :3
Unit Weight (pcf) :149.7

Strength Test Results

Specimen Number Scheduled Test Date Date Tested Age (days) Dia(in.) Area (sq in.) Maximum Loads (lbf) Strength (lbs) % Design Strength Type of Fracture

UNLESS OTHERWISE SPECIFIED, TESTS WERE PERFORMED IN ACCORDANCE WITH ASTM TEST METHODS C31, C39, C138, C143, C173, AND C1064. FRACTURE TYPE INDICATED BY NUMBER.

(Type 1) Cone (Type 2) Cone-split (Type 3) Vertical (Type 4) Shear (Type 5) Edge Fracture (Type 6) Pointed

Field Test Data

Specimen Type Selection : Cylinder

Set Number :D
Date Sampled :03/23/2026
Sampled By :Mahendra Mylabathula
Contractor :COLMAN
Truck Number :31
Time Batched :N/A
Location of Placement :F20
Number of samples cast :5
Ambient Temperature (°f) :N/A
Slump (in.) :5
Water added (gal.) :N/A
Laboratory Number :2026-067
Time Sampled :7
Weather Condition :N/A
Concrete Supplier :MORGAN
Mix ID :4000 57-89 SOG NA
Quantity of Load (cu. yd.) :10
Sample Cast :1
Specified Strength :4000
Concrete Temperature(°f) :70
Air Content (%) :2.5
Unit Weight (pcf) :147.6

Strength Test Results

Specimen Number Scheduled Test Date Date Tested Age (days) Dia(in.) Area (sq in.) Maximum Loads (lbf) Strength (lbs) % Design Strength Type of Fracture

UNLESS OTHERWISE SPECIFIED, TESTS WERE PERFORMED IN ACCORDANCE WITH ASTM TEST METHODS C31, C39, C138, C143, C173, AND C1064. FRACTURE TYPE INDICATED BY NUMBER.

(Type 1) Cone (Type 2) Cone-split (Type 3) Vertical (Type 4) Shear (Type 5) Edge Fracture (Type 6) Pointed

Technician Signature / DateCatherine Lanier, March 23, 2026
Reviewer Name / DateKenneth Mosman, April 13, 2026