- Home
- Density Test Report Report ID: 92174
- Edit Download Report
Density Test Report
Date :04/01/2026
Project No :2026C101
Client Company :Artisan
Arrival Time :04/01/2026 13:00
Onsite Hours :05:00
Name of the Project :Seven Hills PHASE 13, UNIT 4 Lots
Project Location :Dallas
Weather :sunny
Departure Time :04/01/2026 18:00
ASEC Technician Name :Samara Simha Reddy Kandi
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 04/01/2026 | 1 | 24.9 | 94.4 | 2025-032 SP | 94.9 | 25.0 | 99.5 | 95 | D6938 | Pass |
| Location : | Lot #42, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | Retest of failing test performed on March 27 | Gauge Serial No. :91487 | ||||||||
| 04/01/2026 | 2 | 21.4 | 86.8 | 2025-032 SP | 94.9 | 25.0 | 91.5 | 95 | D6938 | Fail |
| Location : | Lot #42, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | Retest of failing test performed on March 27 | Gauge Serial No. :91487 | ||||||||
| 04/01/2026 | 3 | 20.1 | 91.3 | 2025-032 SP | 94.9 | 25.0 | 96.2 | 95 | D6938 | Pass |
| Location : | Lot #42, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | Removed top 4-6 inches and Recompacted with loaded truck and sheep foot roller. Retest of failing test performed on March 27 | Gauge Serial No. :91487 | ||||||||
| 04/01/2026 | 4 | 21.7 | 91.1 | 2025-032 SP | 94.9 | 25.0 | 96.0 | 95 | D6938 | Pass |
| Location : | Lot #41, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | Retest of failing test performed on March 27 | Gauge Serial No. :91487 | ||||||||
| 04/01/2026 | 5 | 19.9 | 89.1 | 2025-032 SP | 94.9 | 25.0 | 93.9 | 95 | D6938 | Fail |
| Location : | Lot #41, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | Retest of failing test performed on March 27 | Gauge Serial No. :91487 | ||||||||
| 04/01/2026 | 6 | 25.5 | 92.4 | 2025-032 SP | 94.9 | 25.0 | 97.4 | 95 | D6938 | Pass |
| Location : | Lot #41, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | Removed top 4-6 inches and Recompacted with loaded truck and sheep foot roller. Retest of failing test performed on March 27 | Gauge Serial No. :91487 | ||||||||
Technician Signature / DateSamara Simha Reddy Kandi, April 1, 2026
Reviewer Name / DateKenneth Mosman, April 02, 2026