Skip to content

Density Test Report

Date :03/30/2026
Project No :2025C269
Client Company :Lewis Contracting
Arrival Time :03/30/2026 07:00
Onsite Hours :01:00
Name of the Project :Main St. & First Ave. - Mixed-use
Project Location :Lilburn
Weather :Sunny
Departure Time :03/30/2026 08:00
ASEC Technician Name :Sean Willett

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
03/30/2026 1 13.1 105.4 2026-047 106.7 20.8 98.8 95 D6938 Pass
Location : Water main by Main Street, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :77-19952
03/30/2026 2 11.6 103.4 2026-047 106.7 20.8 96.9 95 D6938 Pass
Location : Water main by Main Street, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :77-19952
03/30/2026 3 12.5 109.6 2026-047 106.7 20.8 102.7 95 D6938 Pass
Location : Water main by Main Street, Elv/Depth :at finished grade
Comment : Gauge Serial No. :77-19952
03/30/2026 4 14.1 107.7 2026-047 106.7 20.8 100.9 95 D6938 Pass
Location : Water main by Main Street, Elv/Depth :at finished grade
Comment : Gauge Serial No. :77-19952
03/30/2026 5 14.8 125.7 2026-047 106.7 20.8 102.6 98 D6938 Pass
Location : Middle of site roadway/parking lot, Elv/Depth :at finished grade
Comment : Gauge Serial No. :77-19952
03/30/2026 6 14.4 107.6 2026-047 106.7 20.8 100.8 98 D6938 Pass
Location : Middle of site roadway/parking lot, Elv/Depth :at finished grade
Comment : Gauge Serial No. :77-19952
03/30/2026 7 16.6 105.7 2026-047 106.7 20.8 99.1 98 D6938 Pass
Location : Middle of site roadway/parking lot, Elv/Depth :at finished grade
Comment : Gauge Serial No. :77-19952
03/30/2026 8 21.5 104.7 2026-047 106.7 20.8 98.1 98 D6938 Pass
Location : Middle of site roadway/parking lot, Elv/Depth :at finished grade
Comment : Gauge Serial No. :77-19952
03/30/2026 8 16.0 109.3 2026-047 106.7 20.8 102.4 98 D6938 Pass
Location : Middle of site roadway/parking lot, Elv/Depth :at finished grade
Comment : Gauge Serial No. :77-19952
Technician Signature / DateSean Willett, March 30, 2026
Reviewer Name / DateKenneth Mosman, April 08, 2026