Skip to content

Density Test Report

Date :04/01/2026
Project No :2026C125
Client Company :Lewis Contracting
Arrival Time :04/01/2026 15:00
Onsite Hours :01:00
Name of the Project :Pittman Park - Garibaldi St. Stormwater
Project Location :Atlanta
Weather :Sunny
Departure Time :04/01/2026 16:00
ASEC Technician Name :Sean Willett

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
04/01/2026 1 20.1 104.6 Proctor 1 104.9 19.8 99.7 95 D6938 Pass
Location : Sewer line, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :77-19952
04/01/2026 2 19.9 104.9 Proctor 1 104.9 19.8 100.0 95 D6938 Pass
Location : Sewer line, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :77-19952
04/01/2026 3 20.6 102.0 Proctor 1 104.9 19.8 97.2 95 D6938 Pass
Location : Sewer line, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :77-19952
04/01/2026 4 20.8 104.3 Proctor 1 104.9 19.8 99.4 95 D6938 Pass
Location : Sewer line, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :77-19952
04/01/2026 5 18.2 105.6 Proctor 1 104.9 19.8 100.7 95 D6938 Pass
Location : Sewer line, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :77-19952
Technician Signature / DateSean Willett, April 1, 2026
Reviewer Name / DateKenneth Mosman, April 13, 2026