- Home
- Density Test Report Report ID: 93264
- Edit Download Report
Density Test Report
Date :04/14/2026
Project No :2025C269
Client Company :Lewis Contracting
Arrival Time :04/14/2026 02:00
Onsite Hours :01:00
Name of the Project :Main St. & First Ave. - Mixed-use
Project Location :Lilburn
Weather :Sunny
Departure Time :04/14/2026 03:00
ASEC Technician Name :Sean Willett
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 04/14/2026 | 1 | 18.7 | 102.9 | 2026-047 | 106.7 | 20.8 | 96.4 | 95 | D6938 | Pass |
| Location : | Town home lots, Elv/Depth :3 to 4 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :77-19952 | |||||||||
| 04/14/2026 | 2 | 21.5 | 102.8 | 2026-047 | 106.7 | 20.8 | 96.3 | 95 | D6938 | Pass |
| Location : | Town home lots, Elv/Depth :3 to 4 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :77-19952 | |||||||||
| 04/14/2026 | 3 | 15.6 | 103.0 | 2026-047 | 106.7 | 20.8 | 96.5 | 95 | D6938 | Pass |
| Location : | Town home lots, Elv/Depth :3 to 4 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :77-19952 | |||||||||
Technician Signature / DateSean Willett, April 14, 2026
Reviewer Name / DateKenneth Mosman, April 23, 2026