Skip to content

Density Test Report

Date :04/17/2026
Project No :2025C211
Client Company :Pulte
Arrival Time :04/17/2026 07:30
Onsite Hours :05:30
Name of the Project :Haley's Bluff - Philadelphia Rd.
Project Location :Jasper
Weather :Sunny
Departure Time :04/17/2026 13:00
ASEC Technician Name :Sean Willett

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
04/17/2026 1 23.2 95.6 FP 3 100.5 20.5 95.1 95 D6938 Pass
Location : Retaining wall 1, Elv/Depth :18 baskets
Comment : Gauge Serial No. :77-19952
04/17/2026 2 23.7 96.3 FP 3 100.5 20.5 95.8 95 D6938 Pass
Location : Retaining wall 1, Elv/Depth :18 baskets
Comment : Gauge Serial No. :77-19952
04/17/2026 3 20.3 101.5 FP 3 100.5 20.5 101.0 95 D6938 Pass
Location : Retaining wall 1, Elv/Depth :18 baskets
Comment : Gauge Serial No. :77-19952
04/17/2026 4 25.5 92.6 FP 3 100.5 20.5 92.1 95 D6938 Fail
Location : Retaining wall 1, Elv/Depth :19 baskets
Comment : Gauge Serial No. :77-19952
04/17/2026 5 21.3 97.4 FP 3 100.5 20.5 96.9 95 D6938 Pass
Location : Retaining wall 1, Elv/Depth :19 baskets
Comment : Gauge Serial No. :77-19952
04/17/2026 6 22.8 93.2 FP 3 100.5 20.5 92.7 95 D6938 Fail
Location : Retaining wall 1, Elv/Depth :19 baskets
Comment : Gauge Serial No. :77-19952
04/17/2026 7 22.7 96.8 FP 3 100.5 20.5 96.3 95 D6938 Pass
Location : Retaining wall 1, Elv/Depth :19 baskets
Comment : Gauge Serial No. :77-19952
Technician Signature / DateSean Willett, April 17, 2026
Reviewer Name / DateKenneth Mosman, April 23, 2026