Skip to content

Density Test Report

Date :04/22/2026
Project No :2026C103
Client Company :Artisan
Arrival Time :04/22/2026 07:30
Onsite Hours :02:30
Name of the Project :NW PH 2, UNIT 4
Project Location :Dallas
Weather :Sunny
Departure Time :04/22/2026 10:00
ASEC Technician Name :Sean Willett

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
04/22/2026 1 7.8 110.2 2025-035 SP 107.8 13.0 102.2 95 D6938 Pass
Location : B-12 to B-13, Elv/Depth :3 to 4 feet below finished grade
Comment : Gauge Serial No. :77-19952
04/22/2026 2 7.2 110.2 2025-036 SP 107.0 18.5 103.0 95 D6938 Pass
Location : B-12 - B13, Elv/Depth :3 to 4 feet below finished grade
Comment : Gauge Serial No. :77-19952
04/22/2026 3 10.1 102.2 2025-036 SP 107.0 18.5 95.5 95 D6938 Pass
Location : B-14 to B-15, Elv/Depth :3 to 4 feet below finished grade
Comment : Gauge Serial No. :77-19952
04/22/2026 4 8.7 94.5 2025-036 SP 107.0 18.5 88.3 95 D6938 Fail
Location : B-14 to B-15, Elv/Depth :3 to 4 feet below finished grade
Comment : very dry soil Gauge Serial No. :77-19952
04/22/2026 5 8.0 100.9 2025-036 SP 107.0 18.5 94.3 95 D6938 Fail
Location : B-14 to B-15, Elv/Depth :3 to 4 feet below finished grade
Comment : very dry soil Gauge Serial No. :77-19952
04/22/2026 6 8.4 110.5 2025-036 SP 107.0 18.5 103.3 95 D6938 Pass
Location : B-12 to B-13, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :77-19952
04/22/2026 7 8.1 118.0 2025-036 SP 107.0 18.5 102.1 95 D6938 Pass
Location : B-12 to B-13, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :77-19952
04/22/2026 8 11.3 96.4 2025-036 SP 107.0 18.5 90.1 95 D6938 Fail
Location : B-12 to B-13, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :77-19952
04/22/2026 9 (retest) 14.7 83.5 2025-036 SP 107.0 18.5 78.0 95 D6938 Fail
Location : B-12 to B-13, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :77-19952
04/22/2026 10 (retest) 11.3 97.7 2025-036 SP 107.0 18.5 91.3 95 D6938 Fail
Location : B-12 to B-13, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :77-19952
04/22/2026 11 (retest) 12.5 93.2 2025-036 SP 107.0 18.5 87.1 95 D6938 Fail
Location : B-12 to B-13, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :77-19952
04/22/2026 12 (retest) 9.2 106.5 2025-036 SP 107.0 18.5 99.5 95 D6938 Pass
Location : B-12 to B-13 , Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :77-19952
Technician Signature / DateSean Willett, April 22, 2026
Reviewer Name / DateKenneth Mosman, April 27, 2026