Skip to content

Density Test Report

Date :04/22/2026
Project No :2026C101
Client Company :Artisan
Arrival Time :04/22/2026 10:00
Onsite Hours :03:00
Name of the Project :Seven Hills PHASE 13, UNIT 4 Lots
Project Location :Dallas
Weather :Sunny
Departure Time :04/22/2026 13:00
ASEC Technician Name :Sean Willett

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
04/22/2026 1 18.8 93.4 Field proctor #6 98.0 17.2 95.3 95 D6938 Pass
Location : D-11 to D-12 to D-13, Elv/Depth :3 to 4 feet over pipe
Comment : Gauge Serial No. :77-19952
04/22/2026 2 15.1 90.1 Field proctor #6 98.0 17.2 91.9 95 D6938 Fail
Location : D-11 to D-12 to D-13, Elv/Depth :3 to 4 feet over pipe
Comment : Gauge Serial No. :77-19952
04/22/2026 3 13.0 99.4 Field proctor #6 98.0 17.2 101.4 95 D6938 Pass
Location : D-11 to D-12 to D-13, Elv/Depth :3 to 4 feet over pipe
Comment : Gauge Serial No. :77-19952
04/22/2026 4 13.9 97.5 Field proctor #6 98.0 17.2 99.5 95 D6938 Pass
Location : D-11 to D-12 to D-13, Elv/Depth :3 to 4 feet over pipe
Comment : Gauge Serial No. :77-19952
04/22/2026 5 17.8 93.7 Field proctor #6 98.0 17.2 95.6 95 D6938 Pass
Location : D-11 to D-12 to D-13, Elv/Depth :3 to 4 feet over pipe
Comment : Gauge Serial No. :77-19952
04/22/2026 6 15.0 95.9 Field proctor #6 98.0 17.2 97.9 95 D6938 Pass
Location : D-11 to D-12 to D-13, Elv/Depth :3 to 4 feet over pipe
Comment : Gauge Serial No. :77-19952
Technician Signature / DateSean Willett, April 22, 2026
Reviewer Name / DateKenneth Mosman, April 27, 2026