Skip to content

Density Test Report

Date :04/27/2026
Project No :2026C133
Client Company :Artisan
Arrival Time :04/27/2026 11:30
Onsite Hours :05:00
Name of the Project :Salacoa (AKA Boone Ford Rd) Robert's Dam
Project Location :Calhoun
Weather :Sunny
Departure Time :04/27/2026 16:30
ASEC Technician Name :Clyde Smith

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
04/27/2026 1 14.9 103.7 133-6 (field proctor) 107.8 17.1 96.2 95 D6938 Pass
Location : Fill placement at toe of dam embankment west of spillway, Elv/Depth :984.64
Comment : Gauge Serial No. :91643
04/27/2026 2 15.8 106.7 133-6 (field proctor) 107.8 17.1 99.0 95 D6938 Pass
Location : Fill placement at toe of dam embankment west of spillway, Elv/Depth :684.33
Comment : Gauge Serial No. :91643
04/27/2026 3 16.0 105.2 133-6 (field proctor) 107.8 17.1 97.6 95 D6938 Pass
Location : Fill placement at toe of dam embankment west of spillway, Elv/Depth :685.12
Comment : Gauge Serial No. :91643
04/27/2026 4 15.7 106.1 133-6 (field proctor) 107.8 17.1 98.4 95 D6938 Pass
Location : Fill placement at toe of dam embankment west of spillway, Elv/Depth :686.02
Comment : Gauge Serial No. :91643
Technician Signature / DateClyde Smith, April 27, 2026
Reviewer Name / DateKenneth Mosman, May 05, 2026