Density Test Report
Date :04/24/2026
Project No :2023C159
Client Company :CW Matthews
Arrival Time :04/24/2026
Onsite Hours :
Name of the Project :Airfield Repairs 2021-23
Project Location :HJAIA, Atlanta, GA
Weather :overcast
Departure Time :04/24/2026
ASEC Technician Name :Russell Hendrix
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 04/24/2026 | 1 | 17.3 | 96.8 | 2026-111 | 119.3 | 10.6 | 81.1 | 90 | D6938 | Fail |
| Location : | Area 3, Elv/Depth :First lift after excavation | |||||||||
| Comment : | fail / QA in agreement. requested lowering moisture, recompact | Gauge Serial No. :38069 | ||||||||
Technician Signature / DateRussell Hendrix, April 24, 2026