Skip to content

Density Test Report

Date :05/12/2026
Project No :2026C125
Client Company :Lewis Contracting
Arrival Time :05/12/2026 12:00
Onsite Hours :04:00
Name of the Project :Pittman Park - Garibaldi St. Stormwater
Project Location :Atlanta
Weather :sunny
Departure Time :05/12/2026 16:00
ASEC Technician Name :Samara Simha Reddy Kandi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
05/12/2026 1 18.8 99.9 Proctor 1 104.9 19.8 95.2 95 D6938 Pass
Location : Around 25ft from Manhole F1, Elv/Depth :-6''
Comment : Gauge Serial No. :38069
05/12/2026 2 16.8 117.2 Proctor 1 104.9 19.8 95.6 95 D6938 Pass
Location : Around 50 ft from Manhole F1, Elv/Depth :-6''
Comment : Gauge Serial No. :38069
Technician Signature / DateSamara Simha Reddy Kandi, May 12, 2026