Skip to content

Density Test Report

Date :06/18/2026
Project No :2026C101
Client Company :Artisan
Arrival Time :06/18/2026 08:00
Onsite Hours :04:00
Name of the Project :Seven Hills PHASE 13, UNIT 4 Lots
Project Location :Dallas
Weather :Overcast
Departure Time :06/18/2026 12:00
ASEC Technician Name :Sean Willett

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
06/18/2026 1 20.5 98.8 Field proctor #6 98.0 17.2 100.8 95 D6938 Pass
Location : D-7 to D-8, Elv/Depth :2 to 3 feet over pipeline
Comment : Gauge Serial No. :77-19952
06/18/2026 2 20.8 95.0 Field proctor #6 98.0 17.2 96.9 95 D6938 Pass
Location : D-7 to D-8, Elv/Depth :2 to 3 feet over pipeline
Comment : Gauge Serial No. :77-19952
Technician Signature / DateSean Willett, June 18, 2026
Reviewer Name / DateKenneth Mosman, July 07, 2026