- Density Test Report Report ID: 95608
- Edit Download Report
Density Test Report
Date :06/23/2026
Project No :2025C214
Client Company :Artisan
Arrival Time :06/23/2026 08:00
Onsite Hours :06:30
Name of the Project :NW Unit 4 BRIDGE (Materials Testing)
Project Location :Dallas
Weather :Sunny
Departure Time :06/23/2026 14:30
ASEC Technician Name :Sean Willett
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 06/23/2026 | 1 | 22.7 | 99.2 | 2025-031 SP | 101.0 | 20.7 | 98.2 | 95 | D6938 | Pass |
| Location : | Mount Moriah side bridge abutment, Elv/Depth :6 feet above starting grade | |||||||||
| Comment : | Gauge Serial No. :77-19952 | |||||||||
| 06/23/2026 | 2 | 19.7 | 101.3 | 2025-031 SP | 101.0 | 20.7 | 100.3 | 95 | D6938 | Pass |
| Location : | Mount Moriah side bridge abutment, Elv/Depth :6 feet above starting grade | |||||||||
| Comment : | Gauge Serial No. :77-19952 | |||||||||
| 06/23/2026 | 3 | 19.5 | 123.0 | 2025-031 SP | 101.0 | 20.7 | 101.9 | 95 | D6938 | Pass |
| Location : | Mount Moriah side bridge abutment, Elv/Depth :6 feet above starting grade | |||||||||
| Comment : | Gauge Serial No. :77-19952 | |||||||||
Technician Signature / DateSean Willett, June 23, 2026
Reviewer Name / DateKenneth Mosman, July 07, 2026