Skip to content

Density Test Report

Date :06/25/2026
Project No :2026C125
Client Company :Lewis Contracting
Arrival Time :06/25/2026 08:00
Onsite Hours :9:00
Name of the Project :Pittman Park - Garibaldi St. Stormwater
Project Location :Atlanta
Weather :Sunny
Departure Time :06/25/2026 17:00
ASEC Technician Name :Sean Willett

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
06/25/2026 1 21.4 102.0 2026-112 106.7 17.3 95.6 98 D6938 Fail
Location : Existing to D-3 roadway, Elv/Depth :2 feet below finished grade
Comment : Pumping/deflection of subgrade was observed under trench roller. Probe rod testing exhibited soft soils. Gauge Serial No. :77-19952
Technician Signature / DateSean Willett, June 25, 2026
Reviewer Name / DateKenneth Mosman, July 06, 2026