- Home
- Density Test Report Report ID: 96080
- Edit Download Report
Density Test Report
Date :07/10/2026
Project No :2026C100
Client Company :Artisan
Arrival Time :07/10/2026 11:00
Onsite Hours :04:00
Name of the Project :Naturewalk PHASE 3 (PH 2 Extension) Lots
Project Location :Dallas
Weather :sunny
Departure Time :07/10/2026 15:00
ASEC Technician Name :Samara Simha Reddy Kandi
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 07/10/2026 | 1 | 20.1 | 94.5 | Field proctor #6 | 98.0 | 17.2 | 96.4 | 95 | D6938 | Pass |
| Location : | Future lots, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :38069 | |||||||||
| 07/10/2026 | 2 | 19.1 | 99.4 | 2025-033 SP | 104.0 | 16.2 | 95.6 | 95 | D6938 | Pass |
| Location : | Future lots, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :38069 | |||||||||
| 07/10/2026 | 3 | 18.1 | 100.7 | 2025-033 SP | 104.0 | 16.2 | 96.8 | 95 | D6938 | Pass |
| Location : | Future lots, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :38069 | |||||||||
| 07/10/2026 | 4 | 18.7 | 100.5 | 2025-033 SP | 104.0 | 16.2 | 96.6 | 95 | D6938 | Pass |
| Location : | Future lots, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :38069 | |||||||||
| 07/10/2026 | 5 | 21.3 | 99.5 | 2025-031 SP | 101.0 | 20.7 | 98.5 | 98 | D6938 | Pass |
| Location : | Roadway, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :38069 | |||||||||
| 07/10/2026 | 6 | 25.4 | 90.7 | 2025-032 SP | 94.9 | 25.0 | 95.6 | 98 | D6938 | Fail |
| Location : | Roadway, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :38069 | |||||||||
| 07/10/2026 | 7 | 19.2 | 97.5 | 2025-031 SP | 101.0 | 20.7 | 96.5 | 98 | D6938 | Fail |
| Location : | Roadway, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :38069 | |||||||||
| 07/10/2026 | 8 | 20.1 | 99.3 | 2025-031 SP | 101.0 | 20.7 | 98.3 | 98 | D6938 | Pass |
| Location : | Roadway, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :38069 | |||||||||
Technician Signature / DateSamara Simha Reddy Kandi, July 10, 2026
Reviewer Name / DateKenneth Mosman, July 30, 2026