- Home
- Density Test Report Report ID: 96854
- Edit Download Report
Density Test Report
Date :08/14/2026
Project No :2025C214
Client Company :Artisan
Arrival Time :08/14/2026
Onsite Hours :
Name of the Project :NW Unit 4 BRIDGE (Materials Testing)
Project Location :Dallas
Weather :sunny
Departure Time :08/14/2026
ASEC Technician Name :Russell Hendrix
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 08/14/2026 | 1 | 18.5 | 101.7 | North Bridge mixture | 106.8 | 17.5 | 95.2 | 95 | D6938 | Pass |
| Location : | West side of Bridge - North end, 10 feet from wall, Elv/Depth :3 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :92204 | |||||||||
Technician Signature / DateRussell Hendrix, August 14, 2026
Reviewer Name / DateKenneth Mosman, September 01, 2026
